Page 20 of 51 Changing parameters on distance measuring sensors
mm: the measured distance value is indicated in mm and/or cm
0...100%: the measured distance value is indicated as percentage value of the analogous
characteristic, be-gun from the sensor-near vertex up to the sensor-far vertex
100...0%: the measured distance value is indicated as percentage value of the analogous
characteristic, be-gun from the sensor-far vertex up to the sensor-near vertex
NOISE INTERFERENCE FILTER
Only for pico+ or lcs+ sensors
Interfering ultrasonic signals, which are not produced by the sensor itself can be suppressed by the
activation of the noise interference filter.